Control Valves

Our Products

Control Valves


Pneumatic Operated valve

A pneumatic Operated valve also known as Pneumatic valve, the compressed gas starts to push against the piston or diaphragm walls which causes the valve to actuate.

S.No Parameter Value
01 Operating Temperature 70°C
02 Maximum Continuous Operating Time 30 Minutes
03 Vibration Level 30 g-random 20-2000 Hz
04 Shock Level 50 g, 100 m/sec
05 Operation Intermittend
06 Operational Life 100 hrs
07 Operating Altitude 52 k
S.No Specification Pneumatic type Actuator
01 Type Pneumatically Operated
02 Fluid Media GHe, GN2
03 Working Pressure 320+10 bar(a)
04 Nominal Port dia 4 mm
05 weight 0.5 kg
06 Pneumatic Command Pr 24+1 bar, 20+1 bar
07 Vibration Levels 16.5, 9.0 g

Electrical type Actuator

A Rare Earth Permanent Magnet DC motor fitted with a planetary gear head unit consists of 5 stage 0.2 & 0.3 modules of gears with a Linear output.
S.No Parameter Value
01 Operating Temperature 70°C
02 Maximum Continuous Operating Time 30 Minutes
03 Vibration Level 30 g-random 20-2000 Hz
04 Shock Level 50 g, 100 m/sec
05 Operation Intermittend
06 Operational Life 100 hrs
07 Operating Altitude 52 k
S.No Specification Description
01 Type Motor Operated spool type valve
02 Fluid Media GN2 at ambient
03 Working Pressure 320+10 bar(a) max
04 Supply Voltage 28+4 VDC
05 Valve Current(opening / closing) 160~60 mA
06 Time for Opening / Closing 5~2 sec
07 Nominal Port dia 8 mm
08 Vibration Levels 9 g

Start & Stop Valve

These are typically two solenoid coil wounded in a bobbin at the different winding directions of one after another. It has two power sources, one is for the open coil & another one is for the close coil. If the open coil is energized, the valve gets open, and it remains open even the electrical supply is removed. This is because of the latching effect of the magnets. The valve can get closed while giving the electrical supply to the closed coil. The operating pressure may vary since these are customized ones.
S.No Parameter Value
01 Operating Temperature -40 to 70°C
02 Maximum Continuous Operating Time 30 Minutes
03 Vibration Level 30 g-random 20-2000 Hz
04 Shock Level 50 g, 100 m/sec
05 Operation Intermittend
06 Operational Life 100 hrs
07 Operating Altitude 52 k
S.No Specification Description
01 Type 3 Way Solenoid Operated Latch Valve
02 Fluid Media GN2 & GHe at ambient
03 Working Pressure 25 bar(a) max
04 Time for Opening / Closing 10 Seconds
05 Operating Voltage 28 VDC
06 Weight 0.6 kg

Relief Valves

A 3 port valve and the inlet & outlet port vent port are introduced to release the excess pressure. The function of this valve is to limit or control the pressure until the set pressure is reached. In further, the safety valve removes the extra pressure. The operating pressure may vary since these are customized ones.
S.No Parameter Value
01 Operating Temperature -40 to 70°C
02 Maximum Continuous Operating Time 30 Minutes
03 Vibration Level 30 g-random 20-2000 Hz
04 Shock Level 50 g, 100 m/sec
05 Operation Intermittend
06 Operational Life 100 hrs
07 Operating Altitude 52 k
S.No Specification Description
01 Type 3 Way Solenoid Operated Latch Valve
02 Fluid Media GN2 & GHe at ambient
03 Working Pressure 25 bar(a) max
04 Time for Opening / Closing 10 Seconds
05 Operating Voltage 28 VDC
06 Weight 0.6 kg

Flow Control Valves

These are electromechanical valves that allow the pressure to outlet port based on the electrical input. These kinds of the valve remain open condition until we remove the electrical input. The operating pressure may vary since these are customized ones.
S.No Parameter Value
01 Operating Temperature -40 to 70°C
02 Maximum Continuous Operating Time 30 Minutes
03 Vibration Level 30 g-random 20-2000 Hz
04 Shock Level 50 g, 100 m/sec
05 Operation Intermittend
06 Operational Life 50 hrs
07 Operating Altitude 52 k
S.No Specification Description
01 Type Electrically Operated
02 Fluid Media GHe, GN2 & IPA
03 Port dia 6 mm
04 Operating Pressure 88+5 bar(g)
05 Proof Pressure 132 bar(g)
06 Flow rate Upto 128cc/sec
07 Weight 2 kg

Non-Return Valve

It is a two-port valve, one for pressure inlet and another one is pressure outlet. This kind of valve is also known as a one-way valve reflux valve, a retention valve. The operating pressure may vary since these are customized ones.
S.No Parameter Value
01 Operating Temperature -40 to 70°C
02 Maximum Continuous Operating Time 30 Minutes
03 Vibration Level 16.5 g-random 20-2000 Hz
04 Shock Level 40 g, 100 m/sec
05 Operation Intermittend
06 Operating Altitude 52 k
S.No Specification Description
01 Type Spring Loaded, PoppetType
02 Fluid Media GN2
03 Port dia 6 mm
04 Operating Pressure 88+5 bar(g)
05 Proof Pressure 63 bar(g)
06 Cracking Pressure 1.5 bar
07 Weight 0.2 kg

Pressure Regulators

A valve controls the pressure gases by reducing a high input pressure to control lower output pressure. Thus, they maintain a constant output pressure when there are inlet pressure fluctuations. However, the operating pressure may vary since these are customized ones.
S.No Parameter Value
01 Operating Temperature -40 to 70°C
02 Maximum Continuous Operating Time 30 Minutes
03 Vibration Level 16.5 g-random 20-2000 Hz
04 Shock Level 40 g, 100 m/sec
S.No Specification Description
01 Type Regulator
02 Fluid Media GN2 & GHe
03 Inlet Pressure 330 Bar
04 Outlet Pressure 35 Bar
05 Set Pressure 40 Bar
06 Weight 1.5 kg

Our Center-Of-Excellence Enables to Offer
Great Aerospace Solutions!

Connect with us to explore more ideas. Just a click away...